Kloakbehandlingsteknologi Q&A (XIV)

Jul 19, 2025

Læg en besked

245. Q: Vores fabrik behandler alkohol spildevand . Hovedforholdene er som følger: COD<40000 mg/L pH 5-6SS 20000 mg/L TN 500 mg/L SO42- 35 mg/L Temperature 65-75℃. The proposed process is to set up a solid-liquid separator at the front end of the treatment system and connect it to a USAB+ three-tank oxidation ditch at the back. Is this process suitable? If the UASB process is used, should high temperature or medium temperature be used? What else should be paid attention to in the design? A: (1) Medium temperature is better for anaerobic reaction. If the temperature is too high, it should be cooled down. (2) Since anaerobic reaction is sensitive to water quality, water volume and shock load, a large-capacity regulating tank should be built. This is the basic guarantee for the stable operation of anaerobic reaction. (3) Pretreatment process, coarse and fine screens or grit chambers, nutrient salt and pH control systems should be set up according to the characteristics of water quality. (4) It is better to use EGSB or IC for the anaerobic part, and it is recommended to use Carrousel oxidation ditch for the aerobic part.

 

246. Spørgsmål: behandlingsskalaen for vores plante er 30, 000 m3/d . Vi vedtager hydrolyse + biologisk kontaktoxidationsbehandlingsproces . Efter to års drift, har den sekundære sedimentationsbeholder altid svømmet sludge (belastning af ca. methods but to no avail. We initially believe that the design load of the secondary sedimentation tank is too high. Please confirm. Answer: Although we don't know whether the sludge settling performance is good, from the surface load of the secondary sedimentation tank design, your opinion is correct. There is a misunderstanding now that the contact oxidation tank does not have much Biofilmskur, og overfladebelastningen af sedimenteringstanken kan være højere . Overfladebelastningen af mange sedimentationstanke efter kontaktoxidationstanken svarer til den af den aktiverede slamsedimenteringstank. Dette er forkert . overfladen belastning af membranesedimenteringstanken skal være mindre end for mudens sedimenteringstank, fordi det er nødvendigt Shed Biofilm er normalt dårlig.

 

{{0}} Question: This morning, we found that the DO of the four dissolved oxygen meters in the aeration tank of our sewage station suddenly dropped from 4.0mg/L to nearly 0, and the aeration volume of the biochemical tank was increased. But the DO value still did not rise. Since the display values of De fire opløste iltmålere er de samme, den opløste iltmålerfejl kan udelukkes . Svar: Det skal bekræftes, om der er en masse uorganisk COD, der kommer ind i spildevandet.

 

248. Spørgsmål: Hvordan behandles blyion generelt i elektroplettering af spildevand? Udladning af spildevand har krav til sulfid, men er der nogen krav til sulfat? Svar: Der er mange måder at fjerne blyioner i elektroplettering af spildevand, såsom elektrolyse, adsorption ved adsorbenter, såsom aktivt kul, osv. . Der er ingen grænse for sulfatkoncentration i spildevandsafladningsstandarden .}

 

{{0. anaerobic effect is extremely poor. The effluent COD is about 300mg/L and ammonia nitrogen is 55mg/L. The effluent COD of contact oxidation is 180mg/L and ammonia nitrogen is 35mg/L. I have been cultivating for almost half a year, but the effect is just Denne . Jeg har tilføjet slam mange gange, men det er ubrugelig . Jeg begyndte at tilføje mel for nylig, og det har forbedret lidt . på grund af omkostningsbegrænsninger, tilføjer jeg kun 10 kg mel hver dag . Hvordan kan jeg effektivt dyrke biofilm? Svar: Du skal bekræfte, om de grundlæggende kontrolbetingelser er opfyldt, såsom: den omrørende virkning, temperatur, næringsstofforhold (om fosfor mangler) af den anaerobe tank og alkaliniteten og opløste ilt i kontaktoxidationstanken. Fordi introduktionen er for enkel, kan jeg kun svare som dette.

 

{{0. Spekulerer på, om manglen på at reducere ammoniaknitrogenet er relateret til stigningen i sulfid? Det har været en dag med simming, men situationen har ikke forbedret . driftsbetingelserne har ikke ændret . pludselig blev den som denne . Kun to ting skete i midten: 1. Sulfide steg; 2. torsk steg, og der var olie og vand . efter det, blev lavere, og slammet blev fra brun til sort . Hvad skal jeg gøre nu? Answer: I don't know how high the sulfide concentration is, but from the situation you provided, the possibility of sludge poisoning is not high. The main reason is that insufficient oxygen supply causes sludge anaerobism. Insufficient oxygen is related to the previous situations. The oxygenation amount should be increased as much as possible and the water intake should be reduced. If the oxygenation amount cannot be increased, the sludge discharge amount can be appropriately increased to reduce the sludge concentration. This approach seems to be contrary to the three-phase equilibrium principle because the sludge load is higher, but it is not the case. Because appropriately increasing the sludge discharge amount can discharge more substances adsorbed in the slam, det er også nyttigt at lindre manglen på ilt . Denne behandling vil være bedre .

 

{{0} yld Er et spørgsmål: Kan Iron Hydroxid -bundfaldet fjernes ved hjælp af flotation af tryk? A: Den specifikke tyngdekraft af jernhydroxid -bundfald er relativt stort, så det er ikke egnet til flotation .

 

{{0. Var det deflokkuleret til enkeltorganismer og flød ud med vandet eller aerob fordøjelse? Eller var det kombineret med det ikke-døde slam efter kontinuerlig vandindstrømning og flød ud af sedimentationstanken som små flokke? 2. Efter luftning, indtil en lille mængde slam klæbes til fyldstoffet, skal koncentrationen af ophængt slam reduceres for at lette den hurtige vækst af slammet på fyldstoffet ved fuldt ud at anvende næringsstoffer? På dette tidspunkt, hvad er den passende koncentration af suspenderet slam i vandet? 3. Fast biofilmdannelse på fyldstoffet kan forkorte fejlfindingstiden . Hvilke metoder er befordrende for vedhæftningen af slam til fyldstoffet og den hurtige reproduktion og vækst af slam på fyldstoffet? Svar: 1. Der er nogle sovende aerobe bakterier i det såkaldte døde slam, som vil gendanne deres aktivitet under aerobe forhold . Nogle flygtige faste stoffer kan også nedbrydes af bakterier . Nogle slams vil flyde ud med vand efter deflocculation, og nogle vil blive forskudt gennem bakterier gennem bakterier gennem slam . 2. Efter en lille mængde slam, der klæber til fyldstoffet, udsættes for atmosfæren, skal vandindtagelsen øges (næringsstoffer skal suppleres i tiden) . på dette tidspunkt er det bedst ikke at have sludge i vandet . 3. for at forkorte debuggingstiden, dehydrated Brugt . Koncentreret slam før dehydrering skal bruges til inokulation, eller frøslam skal sprøjtes på fyldstoffet, før vand tilsættes til den biokemiske pool . selvfølgelig er der tekniske krav i den specifikke dyrkningsproces .}

 

{{0. Udløbet af COD er påkrævet at være under 90 mg/l . Den aktiverede slamtank SRT er 9 . 3 timer, kontaktoxidationstank SRT er 4 timer, og den mellemliggende sedimenteringstank og den sekundære sedimenteringstank srt er 2 timer . efter den første sludge, der ikke var nogen, og kontinuerlig reflux var båret blev båret blev båret. out. The foam and odor were very heavy, and the removal rate of the biochemical pool could not be improved. Later, the second sludge was added, and the effect was obvious after a few days of aeration and gradually increasing the amount of treated water. The effluent COD of the physical and chemical process was about 700-1000 mg/L, and Torsken for den mellemliggende sedimenteringstank var mere end 200 mg/l . Efter kontaktoxidation var torsken stadig mere end 100 mg/l, hvilket stadig var højere end designkravet (under 90 mg/l) . under operationen, begge den aktiverede slamstank, og kontaktoxidationstanken havde sludge -retur {{29} senere, den aktiverede Sludge Tank, og kontaktoxidationstanken havde sludge return . senere, den aktiverede aktiverede tanktank, og kontakten blev kontaktet tanken havde sludge return {.}, den aktiverede aktiverede tanke blev justeret, blev justeret, blev justeret, der blev justeret. to return, and the contact oxidation tank was not returned. However, the foam in the contact oxidation tank increased. The secondary sedimentation tank was drained for a few minutes every two hours, but the effluent still contained a lot of SS, and the removal effect was not improved. Now I have a few questions to ask: 1. When Er det passende at begynde at dræne slam efter at have tilføjet slam? Hvad er standarden (ingen betingelser for at måle SVI og MLSS)? 2. Det samlede fosfor i det fysisk -kemiske spildevand er kun et par tiendedele, og C/P er meget lav . slammet i det aktiverede slamtank udvides nu . Jeg spekulerer på, om det er relateret til dette? 3. Hvis du vil beregne mængden af fosfatgødning, hvordan beregnes det? Kan du give et eksempel (effektiv komponent af fosfatgødning: P2O 5=12%)? 4. Når kontaktoxidationstanken ikke returneres, er skummet på pooloverfladen åbenlyst mere, end når det returneres . Er det let for LAS at dække pooloverfladen efter omrøring, når der er mindre ophængt slam i poolen? Er returneringen eller ikke bestemt af dens belastning? Er det muligt at tilføje noget suspenderet slam for at dele belastningen, når MLSS er høj og reducerer det suspenderede slam, når MLSS er lavt og kun er afhængig af membranen til at behandle vandet? {{41. 6. Når SV er så høj som 35-60 skal slamudladningen øges for at fjerne slammet med dårlig afviklingsydelse? Svar: Svarene er som følger: 1. Hvis MLSS ikke kan måles, skal SV måles, hvilket groft kan bestemme mængden af slam og slampræstation . Nu er slamet kun inoculeret og dyrket slam, og der er ikke behov for at overveje slamudladning {{} 48}} Uforsikket phosphor dåse skyde, og der er ikke behov performance and affect sludge growth. Phosphorus should be controlled at about 1% of the BOD5 of the biochemical pool influent. If it is insufficient, it should be added, and it is also necessary to confirm whether N meets the requirements. 3. If BOD5 is not measured, the amount of phosphorus added can only be roughly determined by trial and error. The phosphorus concentration is expressed as elemental phosphorus. If X kg of pure phosphorus is added per hour, the amount of 12% P2O5 to be added=X×P2O5/P×12%. 4. It is normal that the foam on the surface of the contact oxidation pond is obviously more than that when it is reflowed after the contact oxidation pond is not reflowed. Now using the reflowed sludge to reduce the foam is a superficial treatment, not a fundamental solution. Generally speaking, the foam will decrease after the biofilm is fully formed. If it still cannot disappear, it can be sprayed with water For at eliminere skummet . 5. kan dit nuværende slam ikke betragtes som ekspansion . Det kan stadig være et problem med næringsforhold . pH -værdien for det biokemiske damindløb, der ikke kan kontrolleres under 6 ~9. Derudover skal det være opmærksom på, at slams vil være til at blive genudviklet under den normale drift af den normale, at der vil være en kontakt med, at det vil blive tilsluttet under, at det vil være til at blive betalt under den normale, at der skal dreje oxidationsmetode . Det kan reflekteres korrekt i kulturperioden, men den kan ikke reflekteres, når ernæring er utilstrækkelig ., hvis næringsstofforholdet ikke er tilfreds, og tilføjer slam er ubrugelig.

 

{{0. Hvis der findes et stort antal klokkeorme og forgrenede orme i slammikroskopisk undersøgelse og er aktiv, kan det overvejes, at biofilm med kontaktoxidation er vellykket, og der er ikke behov for at returnere den (på enkle termer, hvordan man kontrollerer tilbagevenden, skal det kun stoppes, når vandet er fuldt belastet)? A: Hvis der er en lille mængde biofilm på fyldstoffet, behøver slammet i den sekundære sedimentationstank ikke at returneres, ellers vil mikroorganismerne i slammet konkurrere om næringsstoffer med mikroorganismer rolle . modenheden af slamdyrkning kan groft bedømmes ud fra den biologiske fase . Nogle svømningsprotozoer vises, når slammet oprindeligt er dannet {., hvis klokkeormer og forgrenede orms vises i stort antal, og det er generelt, at det generelt kan betragtes som, at kontakten oxidation biofilm er, at der er engrænse. Undtagelser . Nogle affaldsbehandlingsenheder fungerer normalt, men der er få eller endda ingen fast cilieret protozoa, så det er nødvendigt at kombinere SV og andre faktorer til analyse . efter den første dannelse af biofilm, hvis der ikke er nogen særlig situation, er sludge i den sekundære sedimenteringstank, der ikke behøver at blive tilbage.

 

255. Q: Efter den anaerobe slam fra den almindelige åbne anaerobe forvirrede reaktor går tabt, hvordan styres returvolumen? Hvordan installeres en omrører? Hvis der bruges en nedsænket omrører, hvor meget kontrolområde kræves? A: Mudder og vandblanding af den forvirrede anaerobe reaktor opnås ved at skifte op og nedstrømning af vand, så der er ikke behov for at installere en omrører . Der er mange grunde til tabet af anaerob slam, som ikke blot kan knyttes til returvolumen .

 

256. Q: Er luftning under vandindstrømning i kontaktoxidationsdammen ikke befordrende for dannelsen af biofilm? Tilsættes næringsstoftilsætningen til hver biokemisk tank før eller efter vandindstrømning? Vil tilsætningen under vandindstrømning forårsage næringstab? A: I processen med biofilmdyrkning er næringsstoftab uundgåeligt, uanset om det er luftning eller vandstrømsluftning, og den eneste måde er at minimere tabet . Jeg tror ikke, at luftning under vandindstrømning ikke er befordrende for dannelsen af biofilm . Tasten til kontinuerlig vandindflytning er at kontrollere vandbetjeningen og tilføringsvolumenet .}

 

{{0. spildevand er ca. 300 mg/l (kravet er den første niveau omfattende udladningsstandard, COD100 mg/l eller mindre) . Kontaktoxidationsudstrømningens torsk er faldet til ca. 200 mg/l og kan ikke reduceres mere} nu vil vi bruge Pure OxyGen, hvis det fortsætter med at blive aereret, det vil stige igen . nu vi ønsker at bruge Pure OxyG Pilot test for at se, om det fungerer, og planlægger også at tilføje aktivt kul til at prøve . Er der andre måder? A: Ud over at udelukke faktorer, der er relateret til driftskontrol, hvis COD kun kan reduceres til ca. 200 mg/l, betyder det, at B/C -forholdet mellem spildevandet er for lavt; Hvis det fortsat bliver luftet, vil den stige igen, hvilket indikerer, at luftningstiden er for lang, og biofilmen har ældet og delvist opløsning . er grunden til at bruge rent iltluftning, fordi luftningstanken ikke kan levere nok ilt? Hvis spildevandet har dårlig bionedbrydelighed, er ren iltluftning ubrugelig . Tilføjelse af aktivt kul er nyttigt, men det er ikke økonomisk . Jeg føler, at denne proceskombination er problematisk, og jeg ved ikke, hvad forbehandlingsprocessen er før den anaerobe proces, så jeg kan ikke kommentere yderligere .}}}

 

{{0. Hvordan løses det? Answer: I don't know whether you use CAF or DAF. According to what you said, floccules are produced after adding the agent, but the flocculation effect is not very good. This requires confirming whether there is a problem in the agent addition process. PAC and PAM cannot be added at the same time. There should be separate addition units, and there should Vær også en ordentlig blanding og omrøring af flokkuleringsproces . Hvis faktoren for tilsætning af reagenser er udelukket, er det problemet med flotationsfaciliteter og udstyr, såsom: utilstrækkelig gas-væske-interface; Hvis der er en lufttank, skal du bekræfte, om trykkets tryk er normalt;

 

259. Q: Er luftning under vandtilstrømning til kontaktoxidationsdammen, der er skadelig for dannelsen af biofilm? Tilsættes næringsstoftilsætningen til hver biokemisk tank før eller efter vandindstrømning? Vil næringsstoftilsætningen under vandindstrømning forårsage næringstab? A: I processen med biofilmdyrkning er næringsstoftab uundgåeligt, uanset om det er luftning eller vandindstrømning, og den eneste måde er at minimere tabet . Jeg tror ikke, at luftning under vandindstrømning er til skade for dannelsen af biofilm {. nøglen til kontinuerlig vandindflytning er at kontrollere vandbetjenten og tildelt volumen {.}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}