Unormal bedømmelse og justering under spildevandsbehandlingsdrift (II)

Jul 27, 2025

Læg en besked

 

Den fysiske og kemiske zone har dårlig flokkuleringseffekt

 

 

The physical and chemical zone of industrial wastewater treatment refers to a specific area or process stage in which physical and chemical methods are used to treat wastewater during the treatment of industrial wastewater. It mainly removes or separates pollutants in wastewater through physical and chemical reactions to achieve the purpose of improving water quality and create conditions for subsequent biological treatment or deep treatment. The main treatment processes in the physical and Kemisk zone inkluderer koagulation og sedimentation, flotation, filtrering, adsorption og kemisk oxidation og reduktion . Den fysiske og kemiske zone spiller hovedsageligt rollen som forbehandling eller dyb behandling i spildevandsbehandling og kan forbedre stabiliteten af vandkvaliteten i den forreste ende af det biokemiske system .}}}

 

1. manifestationer af dårlig flokkuleringseffekt i den fysiske og kemiske zone

Manifestationen af dårlig flokkuleringseffekt i den fysiske og kemiske zone manifesteres først i kropstilstanden med flokkuler . Under normale omstændigheder, efter at flokkulanten er tilsat, vil den forurenende partikler i vandet for danne større flokkuler . Men når flokkuleringseffekten ikke er god, er den flokke, der er let, formet, formede er åbenlyst, at være åbenlyst, når den er let, at være let, at være let, er let, at det er let, at de er let, at de er let, at de er let, er let, at de er let, at de er let, at de er let, at de er let. Og det er vanskeligt at effektivt fjerne dem gennem efterfølgende processer såsom sedimentering eller filtrering . Strukturen af de genererede flokkuler er ikke stram, men løs, og det er let at bryde under vandstrømmen, og det kan ikke afvikle eller flyde, der påvirker vandkvalitet flocculation effect is not good, the water body is still turbid and has poor light transmittance, indicating that there are still a large number of suspended pollutants in the water that have not been effectively flocculated. If the flocculation effect is not good, the color of the water body will not become significantly lighter as expected during the flocculation process, indicating that the colored pollutants in the water have not been fully flocculated og fjernet . igen, hvad angår specifikke vandkvalitetsindikatorer, manifesteres det som lav fjernelse af suspenderede faste stoffer (SS), manglende reduceret kemisk iltbehov (COD) og overdreven turbiditet .

 

I behandlingsprocessen vil det bremse sedimenteringshastigheden for sedimenteringstanken, få slam til at flyde, gøre filtrering vanskelig, øge doseringen af agenten og forlænge behandlingsprocessen .

 

2. analyse af årsagerne til den dårlige flokkuleringseffekt i den fysiske og kemiske zone

The poor flocculation effect in the physical and chemical zone is related to many factors, mainly including excessive dispersant content in the influent wastewater, non-optimal dosage of flocculants and coagulants, pH value, fast and slow mixing problems, load flow relationship, suspended particle content in the wastewater, and excessive content of non-flocculating substances. Regarding the above influencing factors, a Detaljeret fejlanalyse udføres under .

 

1. faktorer, der påvirker flokkulanter

(1) Forkert valg af flocculants . Forskellige industrielle spildevand har forskellige sammensætninger . Hvis de valgte flokkulanter ikke matcher forurenende stoffer i spildevand Neutraliser overfladeladningen af kolloiderne, kolloiderne kan ikke destabiliseres og aggregeres .

)

(3) Doseringen af flokkulanter er ikke passende . Hvis doseringen er for lille, vil den ikke give nok flokkuleringssteder, og forurenende stoffer vil ikke blive fuldt aggregeret ., hvis doseringen er for stor, kan partikeloverfladen genoplades, hvilket resulterer i redispersionen af de formede flokkuler og forekomsten af forekomsten af forekomst "Deflocculation" .

 

2. faktorer, der påvirker kvaliteten af det påvirkende vand

(1) The pH value of the wastewater will affect the hydrolysis reaction of the flocculant and the existence form of the pollutants. Different flocculants have their appropriate pH ranges. For example, aluminum sulfate has a better flocculation effect when the pH value is 6 to 7.5. Beyond this range, the hydrolysis product morphology of the Flocculant vil ændre sig, hvilket påvirker flokkuleringseffekten .

(2) Temperaturen på spildevandet har en signifikant effekt på flokkuleringseffekten . Når vandtemperaturen er lav, øges vandets viskositet, den browniske bevægelse af partiklerne svækkes, chancen for kollision mellem flokkulanten og den forurenende partikler falder, og hydrolysens reaktionshastighed af flokkulanten også slukes ned, hvilket resulterer i en dårlig flokering Effekt .

(3) The raw water composition of wastewater is complex. Industrial wastewater may contain a variety of pollutants, such as organic matter, heavy metal ions, surfactants, etc. These substances may interact with each other and interfere with the combination of flocculants and pollutants. For example, some organic matter may be adsorbed on the surface of the flocculant, hindre kontakten mellem flokkulanten og suspenderede partikler og reducere flokkuleringseffekten .

(4) Indholdet af suspenderede faste stoffer i råvandet vil også føre til dårlig flokkuleringseffekt . Når koncentrationen af suspenderede faste stoffer (SS) er affaldet er for høj, er en stor mængde flokkulant til at blive konsumeret til fuldt ud at flokke, at partiklerne er for en relativ mangel på flokulanter {2}, når ss -koncentrationen er for lav, for en relativ mangel på flokulant Kollisionsmuligheder mellem partikler, som ikke er befordrende for dannelsen af flokkuler .

 

3. faktorer, der påvirker udstyr og drift

(1) Med hensyn til drift er forkert omrøringsintensitet og tid og utilstrækkelig reaktionstid også vigtige påvirkningsfaktorer . Hvis omrøringsintensiteten er for høj, og tiden er for lang, vil de dannede flokkuler blive brudt, og flokkuleringseffekten vil blive påvirket; if the stirring intensity is too low and the time is too short, the flocculant and wastewater will not be mixed evenly and the flocculation reaction will not be sufficient. The flocculation reaction requires a certain amount of time to fully aggregate the pollutant particles to form larger floccules. If the reaction time is too short, the flocculation reaction is incomplete, which will lead to dårlig flokkuleringseffekt .

)

(3) Modforanstaltninger og justeringsstrategier for dårlig flokkuleringseffekt i den fysisk -kemiske zone er der mange grunde til den dårlige flokkuleringsydelse af partikler i den fysisk -kemiske zone . Hvis klar identifikation og sondring ikke er foretaget under analyse og vurdering, er den symptomatiske behandling ofte ikke muligt, og resultatet er, at sedimenteringspresset på en side af den primære sedimentstank er meget høj {{2 En omfattende analyse af mestringsstrategierne for dette mere besværlige driftsproblem udføres .

1. The content of neutral particles in the wastewater is too high. We know that only by breaking the stability between particles in the wastewater can these suspended particles be destabilized and adsorbed to each other, and finally form coarse flocs under the action of flocculants and be settled and separated from the water body. However, when the Spildevand, der er stødt på, er rig på neutrale ladede partikler, det er ret vanskeligt at udøve ioniseringsadsorptionseffekten af flokkulanten . For at forbedre koagulationseffekten af denne type spildevand, øger nogle operatører ofte blindt doseringen af koagulanter og flocculants {. som et resultat, hvilket ikke er en forbedring af koaguleringseffekten Set . Årsagen er, at stabiliteten af neutralt ladede partikler er ekstremt høj, og det er meget vanskeligt at bryde denne stabilitet . Tværtimod, tilføjelse af for meget koagulant og flokkulant vil forårsage, at den oprindeligt destabiliserede suspenderede partikler til at stabilisere sig igen . Derfor, når man støder på en sådan situation, er det ikke tildelt til at tilføje overdreven beløb til at stabilisere sig for at stabilisere flocculants .

{{0 eder I spildevand svinges for meget, vil det have en stor indflydelse på koagulationseffekten af det fysiske og kemiske område . Som en kontinuerlig driftsmiljøbeskyttelsesfacilitet, har operatører en bestemt inspektionsperiode ., hvis den pludselige inspektion ikke observeres nok, der er en situation, hvor koagulationseffekt Sedimenteringstank . Derfor bør der rettes særlig opmærksomhed under inspektionen med fokus på klarheden i det interstitielle vand mellem spildevandspartikler og tætheden mellem partiklerne efter tilsætning af koagulanter . selvfølgelig, hvis indholdet af suspenderede partikler i påvirkningen af det spildevand er forudsagt at være for høj på de påvirkede sider, vil det være let at gøre det let til at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre det let at gøre, hvis suspenderede partikler i påvirkningen af den indflydelse, der er forudsat at Justeringer . Med hensyn til dosering er det uundgåeligt at øge doseringen af koagulanter og koagulanter til spildevand med høje suspenderede partikler, men doseringen skal bekræftes omhyggeligt .

3. forkert doseringsposition fører til dårlig koagulering og sedimentationseffekt i den fysisk -kemiske zone . Doseringspositionen i den fysisk -kemiske zone er relateret til den tid, det tager for spildevand Korrekt . Normalt er doseringspositionen af koagulanten relativt fast, som er i den hurtige blandetank eller den forreste rørmikser . Dog doseringspositionen af den langsomme blanding af den langsomme blanding af den langsomme blanding af den langsomme blanding, der er i den første, der blander, at den første langsomt blanding. og ser det sjældent ved vandindløbet på den anden langsomme blandetank . Dette skyldes hovedsageligt designårsager . Imidlertid er der følgende problemer i faktisk drift .

1) When the amount of water entering the physicochemical zone reaches the design load, we can find that placing the dosing position of the coagulant aid at the water inlet of the first slow mixing tank is in line with the principle of the best dosing point. Because when the water volume of the physicochemical zone reaches the design load, the flow rate of the physicochemical zone is the largest, and the residence time of Det kemiske middel, der er føjet til spildevandet, er den korteste . For at maksimere agentens opholdstid i den fysisk -kemiske zone efter dosering er vandindløbet af den langsomme blandetank valgt som det bedste doseringspunkt .

2) Når vandvolumen, der kommer ind i den fysisk -kemiske zone, er langt fra designbelastningen, vil vi opdage, at det er forkert at stadig indstille Pam -doseringspunktet i spidsen for vandindløbet i den første langsomme blandetank .

3)Because excessively extending the residence time of PAM in the wastewater will cause the formed flocs to break or deflocculate, which is not conducive to the sedimentation effect of the primary sedimentation tank. In order to deal with this situation, dosing points should be set in both slow mixing tanks. When the water flow rate of the physicochemical zone is small, the PAM Doseringspunkt, der er indstillet i den anden langsomme blandetank, kan åbnes; Når vandstrømningshastigheden er for stor, kan doseringspunktet for den første langsomme blandetank åbnes . En sådan fleksibel selektion og differentiering af doseringspunkter kan maksimere doseringseffekten af Pam -koagulant .

4) For other issues, we still need to make comprehensive adjustments based on the reasons analyzed. From the aspect of equipment technology, optimize the stirring intensity and time, increase the inspection and maintenance equipment, increase or decrease the flocculation reaction time. From the aspect of reagents and water quality, adjust the dosage, change the type of flocculant, adjust the use of coagulant aid, control the water Temperatur, homogeniser råvandskvaliteten, og juster den relevante flokkulering pH -værdi . fra aspektet af personaleovervågning og styring, vandkvalitetsovervågning og personaleuddannelse og styring kan styrkes .

 

4. på stedet i lille skala af dosering

Doseringens rationalitet i det fysiske og kemiske område har en tæt indflydelse på den endelige koagulationseffekt . For bedre at sikre nøjagtigheden af doseringen på stedet er det nødvendigt at udføre et kopflaskeeksperiment. {..

1) containere: 4 1000 ml bægerglas; 4 glasstænger (ca. 20 cm); 2 pipetter (1 ml en, 5 ml en; et ur (til timing); 2 100 ml små bægerglas .

2) reagenser: 0 . 1% PAM 100 ml; 10% PAC 100 ml.

3) Reagensforberedelsesmetode .

Preparation of 0.1% PAM solution: Weigh 10mg solid PAM powder on an electronic balance, prepare 800mL tap water in a 1000mL beaker, place the beaker on an electromagnetic heating stirrer, put a magnetic stirrer in the beaker, and turn on the magnetic stirrer. When the water is stirred evenly, slowly pour a small amount of Vejede Pam -faste partikler i bægerglas . Når den magnetiske omrører roterer kontinuerligt, er Pam -partiklerne, der kommer ind i vandkroppen, jævnt fordelt i vandlegemet og er kontinuerligt opløst og omrørt . efter ca. 2 timer, vi kan opdage, at Pam -stoffet er blevet fuldstændigt opløset. pour pam -opløsningen i Beren til en ber, vi kan opdage, at Pam -stoffet er blevet fuldstændig 1000 ml volumetrisk kolbe, tilsæt ledningsvand for at fortynde til den specificerede skala, og derefter fremstilles 0 . 1% koncentration PAM -opløsningen . Den forberedte opløsning kan normalt opbevares i ca. 1 uge. Hvis det overstiger en uge, vil de aktive ingredienser blive nedbrydet alvorligt og skal genforberedes, om det skal bruges.

Fremstilling af 10% PAC-opløsning: Forberedelsestrinnene på 10% PAC-opløsning er relativt enkle . Normalt kommer PAC-opløsningen, der bruges på stedet i spildevandsrensningsanlæg, fra nærliggende kemiske virksomheder, så de fleste af dem giver kun forberedt PAC-løsninger, som er mest økonomiske til at tilføje ved en koncentration på 10% . Vi har kun brug for at udtrække nogle af de blev bygget PAC, men i en koncentration af den indskrev Koncentration, for nøjagtigheden af dataene, er det nødvendigt at bekræfte, om den købte PAC -opløsning er i en koncentration på 10%, fordi mange producenter vil reducere koncentrationen for at få flere fordele . om koncentrationen er kvalificeret kan bekræftes af et hydrometer eller ved den nationale standard PAC -indholdsdetektionsmetode .}}

4) Bestemmelse af strømningshastigheden for koagulant- og koagulanthjælp under de aktuelle driftsbetingelser . Det er en besværlig proces at bestemme strømningshastighed 1 1000 ml målecylinder og 1 stopwatch . Detektionsmetoden er: Brug en 1000 ml målecylinder til at modtage pac, der flyder ud af røret ved pac -dosering af outlet {{7}, når det begynder at strømme ind i den målende cylinder, tryk på stopwatch for at starte timing {{{8} Fjern målet the highest scale, and press the stopwatch to stop timing. Observe the amount of PAC solution in the measuring cylinder and divide it by the number of seconds obtained by timing to get the second flow rate of PAC solution. The same method can detect the dosing flow of PAM, but in the actual PAM dosing site, most of the PAM is multi-point dosing, which brings inconvenience to USA til at samle PAM -løsning på en centraliseret måde . Heldigvis er de fleste af PAM -doseringsrør

3 Koagulant hjælp har vigtig praktisk vejledende betydning, og gør også sammenligneligheden af doseringen kvantificeret . Bestem doseringen i henhold til strømningshastigheden for den tilsatte koagulant: forudsat at doseringsstrømmen for PAC er 1000 ml ./min, den faktiske mængde PAC -tilføjet til vandkroppens er 1000 ml × 10%=100 ml . Baseret på den antagede densitet på 1 . 0, er den faktiske vægt af PAC tilføjet til vandmassen pr. Minut 100000 mg . under forudsætning af, at den spildevandsbehandlingsstrømning på denne tid er 500m3/h, den behandlede vandstrømning pr. Minut er en minut er 8 {{24. then the actual amount of PAM added to the water body is 12000mL×0.05%=6mL. Based on the assumed density of 1.0, the actual weight of PAM added to the water body per minute is 6000mg. Let's confirm that the wastewater treatment flow rate at Denne gang antages at være 500m3/h, så er den behandlede vandstrømningshastighed pr. Minut 8 . 3m3 (8333L) og den endelige PAM -koncentration tilsat til vandlegemet=6000/8333=0.72 mg/l. Når vi beregnet koncentrationen af koagulant og koagulant tilsat affaldet, kan vi bestemme, om koagulanten og koagulanten tilsat det strømspildevand er den passende dosering gennem en lille test. Hvis der er en fejl i doseringskoncentrationen, kan doseringsstrømningshastigheden af koagulant og koagulant justeres for at imødekomme kravene i den optimale dosering. Hvordan udføres en lille test på stedet? Dernæst giver vi en detaljeret forklaring. På stedet småskala tests er en færdighed, som personale på stedet skal have personale på stedet skal have, fordi vi allerede ved vigtigheden af det fysiske og kemiske afsnit i hele spildevandsbehandlingsprocessen, og vi ved også, at om doseringen af koagulanter og koagulanter er nøjagtig bestemmer det endelige bundfældesultat af hele fysisk og kemisk sektion.

De specifikke trin på småskala testoperationstrin er som følger:

① Sted 4 1000 ml bægerglas i en operativ og stabil position, injicer det omrørte spildevandsrå vand, og hold væskeniveauet på 1000 ml skalaposition af bægeret .

② Bestem den faktiske koncentration af PAC, der er tilsat på stedet gennem videnpunktet i artikel 5), og bestemm således den svingende dosering, der skal bekræftes i løbet af den lille skala-test . generelt, 0 . 8 gange, 1,0 gange, 1,2 gange og 1,4 gange er værdierne taget til tilføjelse.

③Assuming that the PAC concentration measured on site is 12mg/L, according to the ratio relationship mentioned above, the test concentrations to be added during the small test need to be set to 9.6mg/L, 12mg/L, 14.4mg/L, and 16.8mg/L, and the volumes of PAC (concentration 10%) added to the four beakers are 0,096 ml, 0,12 ml, 0,144 ml og 0,168 ml.

Efter at tilføje Pac til bægerglas, er det nødvendigt hurtigt at røre vandet i bægerglas med en glasstang . i teorien, hvad der skal gøres at røre vandet så hurtigt som muligt, så længe vandet ikke oversvømmer . omrøringstiden kontrolleres på cirka 15 år, og det er nødvendigt at begynde at omrøre og stop med at omrøre i de firbakere på samme røringstid, Tid . Betjeningen af flere personer kræver den samme teknik så meget som muligt .

⑤ Formålet med hurtig omrøring er hovedsageligt at gøre det muligt for den tilføjede PAC hurtigt at blive fordelt i spildevandet på kortest tid . til dette formål, omrøring kan stoppes, når den hurtige fordeling af PAC i vandet er afsluttet .

⑥ Det næste trin er at tilføje PAM eller bekræfte den faktiske koncentration af PAM tilsat på stedet i henhold til videnpunktet i artikel 5) og derved bestemme den svingende dosering, der kræves for at blive bekræftet i løbet af pilotprøven på stedet . generelt, 0 . 8 gange, 1,0 gange, 1,2 gange og 1,4 gange bruges til at bekræfte virkningen.

⑦ Under antagelse af, at den målte koncentration af PAM tilsat på stedet er 0 . 72 mg/l, skal de testkoncentrationer, der kræves for at blive tilsat under pilotprøven, indstilles til 0 {11} 58 mg/l, 0,72 mg/l0,86 mg/l, i henhold til forholdet, der er nævnt ovenfor. Mængderne af PAM (koncentration 0,05%) tilsat til de fire bægerglas er henholdsvis 1,16 ml, 1,44 ml, 1,72 ml og 2,02 ml.

⑧ Før vi tilføjer PAM, har vi allerede tilføjet PAC, så vi kan bekræfte, om den tilføjede PAC opfylder kravene i den optimale dosering ved at observere effekten efter at have tilføjet PAC . De vigtigste observationsemner er for at bekræfte ændringerne i størrelsen af flokpartiklerne, der er dannet i de fire bægter, vil være gam -vandet mellem partiklerne, osv. Omfattende sammenligning af lægemiddelpriseffekten efter den endelige tilføjelse af Pam .

⑨ Efter at have observeret effekten af tilsætning af PAC, skal PAM føjes til bægerglaserne så hurtigt som muligt . mængderne af PAM (koncentration 0 . 05%) tilsat de fire bægerglas er henholdsvis 1,16 ml, 1,44 ml, 1,72 ml og 2,02 ml.

⑩ Efter tilsætning af PAM er det nødvendigt langsomt at omrøre vandet i bægerglas på samme tid, så grove gelfjer gradvist dannes i vandet . Størrelseshastigheden styres ved 40 omdrejninger

⑪ Under omrøringen og ventet på nedbørsprocessen skal der observeres flere poster for at bedømme lægemiddelpriseffekten under forskellige doseringskoncentrationer . De vigtigste elementer er: størrelsen og hastigheden af dannelse af gelfjer; Klarheden i gapvandet mellem gelfjer; Skumsituationen på den flydende overflade osv. .

⑫ Når den dannede gelfjeder forsvinder efter den hydrauliske rotationseffekt, vil den hurtigt komme ind i nedbørstadiet . Efter 30 minutters statisk nedbør, kan vi dosere doseringseffektivitet Graden af gelfjer hængende på bægervæggen, den endelige supernatantskum osv. .

According to the problems of excessive or insufficient addition of PAC and PAM and the inharmonious addition ratio, the best dosing effect can be obtained by carefully confirming and repeatedly adjusting the addition amount of PAC or PAM. This is the main means of guiding the practical dosing operation through on-site small-scale tests. If used well, it is very meaningful for us to achieve efficient dosing Effekter og spar doseringsomkostninger i det fysiske og kemiske afsnit . Det skal påpeges her, at koagulanter og koagulerende hjælpemidler, der er involveret i eksemplerne, er PAC og PAM .

Faktisk er ikke kun det, aluminiumsulfat, polyferisk chlorid, jernchlorid og andre koagulanter også egnede til denne lille skala testmetode, og både anioniske og ikke-ioniske typer PAM er anvendelige; Hvis der bruges kationisk Pam til tilføjelse til spildevand, anbefales det ikke at tilføje PAC og andre koagulanter inden den småskala-test på stedet, men til at tilføje kationisk PAM alene, som også kan opnå bedre koagulation og sedimentationseffekter .

Send forespørgsel
Kontakt oshvis du har spørgsmål

Du kan enten kontakte os via telefon, e-mail eller online formularen nedenfor. Vores specialist vil kontakte dig snarest.

Kontakt nu!